FCPS Part 1 PhysiologyRadiology Paper 2

Heart as a pump

The heart as a pump; dynamics of blood and lymph flow

Cardiac output is set by heart rate and stroke volume, and stroke volume by preload, afterload and contractility. Flow through vessels obeys simple physical laws that also explain Doppler ultrasound findings, and capillary Starling forces decide whether fluid stays in the vessels or forms oedema. CPSP expects quick calculations and the reasoning behind each law.

The cardiac cycle

PhaseValvesKey events
Isovolumetric contractionAll closedPressure rises; first heart sound at its start
Rapid ejectionSemilunar valves open at its startMost of the stroke volume leaves
Reduced ejectionSemilunar openT wave; ventricular systole spans roughly the QT interval
Isovolumetric relaxationAll closedSecond heart sound at its start
Rapid fillingAV valves openDoppler E wave
Atrial systoleAV openDoppler A wave: the "atrial kick", lost in atrial fibrillation (E waves only), poorly tolerated in a stiff hypertrophied ventricle

Output and its determinants

  • Cardiac output = stroke volume × heart rate. Ejection fraction = SV ÷ EDV.
  • Worked examples: EDV 120 mL, ESV 50 mL gives SV 70 mL and EF 58%. CO 5.6 L/min at 70/min gives SV 80 mL; with EDV 145 mL, EF is about 55%. CO 6.6 L/min at 88/min gives SV 75 mL.
  • Preload is best represented by end-diastolic volume. Frank–Starling law: stroke volume rises with EDV because stretched sarcomeres reach a better overlap and calcium sensitivity. A denervated transplanted heart raises output at the start of exercise this way, before its rate changes.
  • Contractility (inotropes such as dobutamine) moves the curve upward: higher SV at the same EDV, so filling pressure falls.
  • Afterload is ventricular wall stress during ejection (Laplace: stress ∝ pressure × radius ÷ wall thickness). Concentric hypertrophy in aortic stenosis keeps wall stress normal. A failing ventricle is very afterload-sensitive, so arterial vasodilators raise its SV.
  • Athletes have a larger SV and a lower resting rate with the same resting output.
  • Fluid responsiveness: a passive leg raise that increases SV by more than about 10% predicts a rise with fluid. High PEEP raises intrathoracic pressure and reduces venous return.
  • In hypertrophic cardiomyopathy, reduced venous return (Valsalva strain) shrinks the cavity and worsens outflow obstruction.
  • Pulse pressure reflects SV and arterial stiffness: wide in aortic regurgitation (large SV plus diastolic backflow) and thyrotoxicosis (large SV, low SVR).
  • Output is measured by the Fick principle or indicator dilution (indocyanine green, thermodilution).
  • An IVC under 2.1 cm that collapses by over 50% on sniffing means a normal right atrial pressure (about 3 mmHg).

Pregnancy and labour

  • Cardiac output rises about 40%, from 4.5 to 6.5 L/min by mid-pregnancy, mainly from stroke volume, later also heart rate.
  • Each contraction squeezes 300–500 mL of blood from the uterus into the circulation (output up a further 15–25%). The highest output and preload come just after placental delivery: the danger point in mitral stenosis.
  • Uterine blood flow at term is about 500–750 mL/min, explaining rapid PPH from an atonic uterus. It is not autoregulated, so it follows maternal blood pressure (fetal bradycardia after spinal hypotension) and is reduced by catecholamines.

Physics of flow

LawStatementApplication
Ohm's law of flowFlow = pressure difference ÷ resistanceBasis of blood pressure regulation
PoiseuilleResistance ∝ viscosity × length ÷ radius⁴Halving radius raises resistance 16-fold; polycythaemia (high viscosity) lowers cerebral flow
ContinuityVelocity ∝ 1 ÷ cross-sectional areaVelocity rises through a stenosis (carotid Doppler grading)
Simplified BernoulliPressure gradient = 4v²4 m/s across the aortic valve gives about 64 mmHg
Reynolds numberTurbulence ∝ velocity × diameter × density ÷ viscosityAnaemia: low viscosity, high velocity, turbulent flow murmurs; helium–oxygen (low density) reduces turbulent resistance in croup
  • In fetal anaemia the middle cerebral artery peak systolic velocity rises (low viscosity, high output).
  • Coronary flow: left coronary flow nearly stops in early systole because the left ventricular wall compresses its vessels; right coronary flow continues because right ventricular wall pressure is lower.
  • Phase-contrast MRI measures flow: pulmonary 8 L/min with aortic 4 L/min is a Qp:Qs of 2:1 (left-to-right shunt).

Capillary exchange and oedema

  • Net filtration pressure = (Pc − Pi) − (πc − πi). Filtration is favoured by capillary hydrostatic and interstitial oncotic pressure.
  • Arterial end: (35 − 0) − (25 − 3) = 13 mmHg outwards. Venous end: (15 − 0) − (25 − 3) = 7 mmHg inwards.
Mechanism of oedemaExample
Raised capillary hydrostatic pressureHeart failure, venous obstruction
Low plasma oncotic pressureCirrhosis, nephrotic syndrome (low albumin)
Increased permeabilityInflammation, sepsis
Lymphatic obstructionTumour, filariasis, surgery
  • Safety factors: while interstitial pressure is negative the tissue is stiff (low compliance), lymph flow rises and protein is washed out. Once pressure rises above zero, compliance jumps and visible oedema appears suddenly.
  • Lymph flow rises with capillary pressure and permeability, and falls if plasma oncotic pressure rises. Muscle contraction compresses lymphatics: patients walk during lymphoscintigraphy.
  • Normal femoral vein Doppler is phasic with breathing; continuous non-phasic flow means proximal (iliac or IVC) obstruction.
  • In the kidney, the same forces apply: obstruction raises Bowman's space pressure and lowers GFR.

Pulmonary venous pressure on the chest X-ray

Wedge pressureRadiograph
13–18 mmHgUpper lobe blood diversion
18–25 mmHgInterstitial oedema: Kerley B lines, peribronchial cuffing
Over 25 mmHgAlveolar (bat-wing) oedema

Remember Resistance depends on the fourth power of the radius: small changes in calibre dominate flow.

Exam trap Ejection fraction is SV divided by end-diastolic volume, not by end-systolic volume.

Exam trap The semilunar valves open at the start of the ejection phase, after isovolumetric contraction.

Test yourself on this topic

5 of the 95 questions in our bank on this topic. Choose an answer to see why every option is right or wrong.

Question 1Medium

The c wave of the jugular venous pulse is produced by:

Question 2Medium

Ventricular systole corresponds to which part of the ECG?

Question 3Medium

Lymph flow is decreased by an increase in:

Question 4Medium

In the ventricular wall, the conducting (Purkinje) system is located in the:

Question 5Medium

According to the Frank-Starling law, the increase in cardiac output is proportional to:

Practise all 95 questions on this topic

Where this sits in the CPSP syllabus

  • Diagnostic Radiology, Paper 2: Cardiovascular, respiratory and renal physiology, Heart as a pump and its regulation; dynamics of blood and lymph flow

Read next