Principles of imaging
Principles of ultrasound, Doppler, X-ray, CT, MRI, radioisotopes and lasers
Every imaging method sends energy into the body and reads how tissues reflect, absorb or re-emit it. CPSP asks the basic physics behind each method, why one frequency, voltage or sequence is chosen over another, and how tissues appear as a result, especially in the pelvis and pregnancy.
One of the most tested topics in past papers
Ultrasound
- Ultrasound is sound above 20 kHz (human hearing is 20 Hz to 20 kHz); diagnostic probes use about 2–15 MHz.
- The probe's piezoelectric crystal vibrates when voltage is applied (transmit) and produces voltage when echoes strike it (receive).
- Echoes arise at boundaries of different acoustic impedance (density × speed of sound). Tissue–air reflects about 99.9%, so coupling gel is used and bowel gas blocks the view; a full bladder displaces gas and gives an acoustic window for transabdominal pelvic scans.
- Depth is calculated from echo time, assuming soft-tissue speed of 1540 m/s (depth = speed × time ÷ 2).
- Wavelength = speed ÷ frequency. Higher frequency means shorter wavelength and better resolution but less penetration, because attenuation rises with frequency.
| Use | Typical frequency |
|---|---|
| Transabdominal obstetric | 3–5 MHz (lower for obese women) |
| Transvaginal (probe close to target) | 5–9 MHz |
| Breast, thyroid, superficial | 10–15 MHz |
- M-mode (motion against time on one line) records embryonic heart rate at low acoustic output.
- Artefacts: acoustic shadowing behind stones, bone and calcification (strong reflection and absorption); posterior acoustic enhancement behind cysts (fluid attenuates little); reverberation (comet tail) between strong reflectors.
- Transvaginal scanning is the best test to localise the placenta in suspected placenta praevia.
Doppler
- Sound reflected from moving red cells changes frequency in proportion to their velocity and the cosine of the beam angle (Doppler shift).
- Colour Doppler: red = flow towards the probe, blue = away (nothing to do with oxygenation); mosaic = turbulence or aliasing.
- Pulsed Doppler samples a chosen depth but aliases when the shift exceeds half the pulse repetition frequency (Nyquist limit); fix by raising the scale or lowering the baseline. Continuous-wave Doppler (two crystals, as in hand-held fetal heart detectors) has no depth information and does not alias.
- Indices: pulsatility index = (S − D) ÷ mean; resistance index = (S − D) ÷ S. As ratios, the angle cancels out, so they are used for umbilical and uterine arteries. Absent or reversed umbilical end-diastolic flow means high placental resistance.
- Pulsed Doppler has the highest thermal output; use it sparingly in the first trimester.
X-rays
- Electrons from a heated cathode strike a tungsten anode, producing mainly bremsstrahlung (braking radiation); about 99% of the energy becomes heat.
- kV controls photon energy and penetration; mAs controls photon number (and dose). High kV lowers contrast.
- Photoelectric absorption (photon fully absorbed, probability proportional to Z³) creates contrast: calcium, iodine (Z 53), barium look white. Compton scatter dominates in soft tissue, fogs the image (reduced by grids) and is the main source of staff dose.
- Mammography uses low kV (25–30 kV) to maximise photoelectric soft-tissue contrast.
Computed tomography
- A rotating X-ray beam takes many projections; the computer calculates attenuation in each voxel (filtered back-projection or iterative reconstruction), removing superimposition.
- Hounsfield units: water 0, air −1000, fat about −100, soft tissue +20 to +60, fresh blood 40–70, bone up to +1000. Fat at −100 HU in an ovarian mass means a dermoid.
- Windowing: level is the centre HU, width the range shown.
- CT carries a much higher dose than plain films.
Magnetic resonance imaging
- Hydrogen protons align in a strong field (1.5–3 T) and precess at the Larmor frequency (about 42.6 MHz per tesla). A radiofrequency pulse at that frequency tips them (resonance); as they relax they emit signal. No ionising radiation.
- T1 (spin–lattice) and T2 (spin–spin) relaxation create contrast:
| Tissue | T1-weighted | T2-weighted |
|---|---|---|
| Water, CSF, urine, cysts | Dark | Bright |
| Fat | Bright (drops with fat suppression) | Bright |
| Subacute blood (methaemoglobin) | Bright (stays bright with fat suppression) | Variable |
| Haemosiderin, iron | Dark | Dark (blooms on gradient echo) |
- Endometrioma stays T1 bright with fat suppression; a dermoid loses signal.
- Gadolinium contrast shortens T1 (enhancing tissue turns bright).
- Hazards: the always-on static field pulls ferromagnetic objects; RF pulses cause heating; gradients cause noise. Pacemakers and some implants are contraindications.
Radioisotopes
- A tracer emits gamma rays detected by a gamma camera (collimator, sodium iodide crystal, photomultipliers).
- Technetium-99m: ideal: half-life 6 hours, pure gamma of 140 keV, no beta (low patient dose), from a molybdenum-99 generator.
- PET: fluorine-18 FDG emits positrons (paired 511 keV photons) and tracks glucose use.
Lasers
- Light Amplification by Stimulated Emission of Radiation: needs a population inversion; light is monochromatic, coherent and collimated, giving high power density when focused.
| Laser | Wavelength | Behaviour and use |
|---|---|---|
| CO2 | 10,600 nm (far infrared) | Strongly absorbed by water: shallow, precise vaporisation (CIN, vulval and vaginal lesions); cannot work through fluid |
| Nd:YAG | 1064 nm (near infrared) | Passes through water and clear fluid: deep coagulation; fetoscopic ablation of placental vessels in twin–twin transfusion |
| Argon | Visible blue-green | Absorbed by haemoglobin and pigment: retinal photocoagulation |
Remember Higher ultrasound frequency sees finer detail but not as deep; that is why the transvaginal probe gives the sharper picture.
Exam trap Red and blue on colour Doppler show direction relative to the probe, not arterial and venous blood.
Exam trap Bright on T1 is not always fat: blood stays bright when fat suppression is applied.
Test yourself on this topic
5 of the 5 questions in our bank on this topic. Choose an answer to see why every option is right or wrong.
A 30-year-old woman one week postpartum has acute chest pain, haemoptysis and an S1Q3T3 ECG pattern without fever. What is the most appropriate investigation?
Answer: CT pulmonary angiogram
The picture is pulmonary embolism: postpartum hypercoagulability, pleuritic chest pain, haemoptysis and S1Q3T3 on ECG. CT pulmonary angiography is the investigation of choice to demonstrate the clot.
Pulmonary embolism
- Postpartum = hypercoagulable
- ECG: S1Q3T3
- Investigation: CT pulmonary angiogram
- Source is usually DVT
Remember Suspected pulmonary embolism is confirmed with CT pulmonary angiography.
Why the other options are wrong
- Chest X-ray Chest X-ray is often normal in embolism and cannot confirm it.
- BNP BNP rises in heart failure and is not diagnostic of embolism.
- CK-MB CK-MB marks myocardial injury, not embolism.
- LDH LDH is a non-specific tissue damage marker.
A radioisotope scan of the thyroid is most clearly indicated in:
Answer: Thyrotoxicosis with a nodule
Isotope scanning shows function, so its main use is in a hyperthyroid patient with a nodular gland to distinguish a toxic (hot) nodule from Graves' disease or toxic multinodular goitre. Euthyroid nodules are assessed by ultrasound and FNAC. How it's asked clinically: A 50-year-old woman has weight loss, tremor and palpitations with undetectable TSH and a single palpable thyroid nodule, but no eye signs or diffuse goitre → isotope scan to show a hot (toxic) nodule.
Thyroid isotope scan
- Isotope scan shows function, not structure
- Hot nodule: toxic adenoma
- Cold nodule: needs FNAC
- Isotopes contraindicated in pregnancy
Remember Isotope scan is mainly indicated in thyrotoxicosis with a nodular thyroid.
Why the other options are wrong
- Euthyroid solitary nodule Assessed by ultrasound and FNAC; scan adds little.
- Goitre in pregnancy Radioisotopes are contraindicated in pregnancy.
- Medullary carcinoma Arises from C cells, which do not trap iodine.
- Anaplastic carcinoma Diagnosed by FNAC or biopsy; does not take up iodine.
A 58-year-old woman who had an early menopause at 42 and has taken prednisolone for 3 years for asthma breaks her wrist after tripping on the pavement. Which investigation is the method of choice to measure her bone density?
Answer: DEXA scan
A low-trauma fracture with early menopause and long-term steroids suggests osteoporosis, which is diagnosed by a T-score at the hip and spine measured with very low radiation. Dual-energy X-ray absorptiometry measures bone mineral density at the spine and hip with very low radiation, and is the standard for diagnosing osteoporosis (T-score). X-ray only shows loss after about 30-40% of bone mass is gone.
Bone density
- DEXA = standard test
- T-score ≤ -2.5 is osteoporosis
- X-ray detects loss only after 30-40%
- Bone scan shows turnover
Remember DEXA is the standard method for bone mineral density.
Why the other options are wrong
- MRI Poor for density; used for marrow and soft tissue.
- Technetium scan Bone scan detects turnover, metastases and fractures, not density.
- CT scan Quantitative CT exists but has higher radiation; not the standard.
- Plain X-ray Insensitive until marked demineralisation.
A 27-year-old woman has six months of amenorrhoea and milky nipple discharge. Serum prolactin is raised, pregnancy test is negative and visual fields are normal. Which imaging is best to look for the cause?
Answer: MRI of the sella
Amenorrhoea, galactorrhoea and high prolactin with normal visual fields suggest a small prolactin-secreting pituitary adenoma, which needs contrast soft-tissue imaging of the pituitary fossa to detect. MRI with contrast shows soft-tissue detail and can detect adenomas smaller than 10 mm, which appear as hypoenhancing areas against the normal gland. CT shows bone better and misses most microadenomas.
Pituitary adenoma
- Microadenoma is less than 10 mm
- MRI with contrast is the imaging of choice
- Macroadenoma may show bitemporal hemianopia
- CT is poor for small sellar lesions
Remember MRI is the imaging of choice for pituitary microadenomas; CT misses most of them.
Why the other options are wrong
- Ultrasound of the neck Evaluates thyroid and neck nodes; cannot image the pituitary.
- CT of the head Poor soft-tissue contrast; misses most microadenomas and is used only if MRI is contraindicated.
- PET scan Used for metabolic staging of cancers; not for a small pituitary lesion.
- Skull X-ray May show a ballooned sella in large tumours only; cannot detect a microadenoma.
Which antepartum assessment combines a non-stress test with ultrasound of fetal breathing, movement, tone and amniotic fluid?
Answer: Biophysical profile
The biophysical profile combines fetal heart-rate assessment with four ultrasound components. Test performance depends on thresholds, population and outcome, so it should not be described as universally the most accurate or lowest-false-positive test.
Antepartum fetal surveillance
- BPP = NST + 4 ultrasound variables
- Variables: breathing, movement, tone, liquor
- NST: high false-positive rate
- CST: low false-negative rate
Remember Biophysical profile gives the lowest false-positive rate of antepartum fetal tests.
Why the other options are wrong
- Doppler of uterine artery Uterine artery Doppler predicts pre-eclampsia and growth restriction risk, not current well-being.
- Non-stress test The non-stress test is simple but has a high false-positive rate (non-reactive in sleeping fetuses).
- Fetal kick count Maternal kick counting is a crude screening tool with many false alarms.
- Contraction stress test The contraction stress test has a low false-negative but a high false-positive rate.
Where this sits in the CPSP syllabus
- Obstetrics & Gynaecology, Paper 2: Biophysics, Principles of ultrasound, Doppler, X-ray, CT, MRI, radioisotopes and lasers